Skip to content
Other

Joules to Volts Calculator

Joules (energy) and volts (electric potential) are linked by electric charge or capacitance. Enter energy in joules plus either the charge in coulombs or the capacitance in farads to calculate voltage in volts. Switch modes to solve for voltage in a capacitor or across any charge-carrying path, and use reverse-solve to find energy or charge from a known voltage.

Your details

Choose how to relate joules and volts. Charge mode uses V = E/Q. Capacitor mode derives voltage from stored energy and capacitance. The two reverse modes find energy from a known voltage.
Energy in joules (J). 1 kJ = 1000 J.
J
Electric charge in coulombs (C). The charge that carries or stores the energy.
C
VoltageIntermediate voltage
50V

Calculated voltage in volts

Energy100J
Charge2C
Power equivalent (per second)100W
Formula appliedV = E / Q
50 V
Low voltage<50Intermediate50-120High voltage120+
05010010105200
Energy (J)
Voltage (V)
Energy (J)Voltage vs energy at Q = 2 C
105
2010
3015
4020
5025
6030
7035
8040
9045
10050
11055
12060
13065
14070
15075
16080
17085
18090
19095
200100

100.00 J with 2.0000 C gives 50.0000 V.

  • A charge of 2.0000 C carrying 100.0000 J of energy corresponds to a potential difference of 50.0000 V.
  • This relationship comes directly from the SI definition of the volt: one volt equals one joule per coulomb (1 V = 1 J/C).
  • Voltages above 50 V can be hazardous. Always follow local electrical safety regulations before working with circuits at this level.

Next stepConsult a licensed electrician before working with voltages in this range.

Formula

V=E/Q(charge mode)V=2EC(capacitor mode)V = E / Q \quad (\text{charge mode}) \qquad V = \sqrt{\dfrac{2E}{C}} \quad (\text{capacitor mode})

Worked example

Charge mode: 100 J / 2 C = 50 V. Capacitor mode: sqrt(2 * 100 J / 0.01 F) = sqrt(20000) ≈ 141.4 V.

Why joules and volts are related but not directly convertible

The volt is defined as the electric potential that does one joule of work on one coulomb of charge: 1 V = 1 J/C. That means energy alone is not enough to determine voltage; you also need to know the charge (or, for a capacitor, the capacitance). This calculator handles both cases: the general charge-based formula V = E/Q, and the capacitor-specific formula V = sqrt(2E/C) that comes from the capacitor energy equation E = (1/2)CV^2.

Charge mode formula explained

In the charge mode, voltage is the ratio of energy to charge: V = E / Q. This follows directly from the SI definition of the volt. If a charge of 2 coulombs carries 100 joules of energy, the potential difference across which that charge moves is 100 / 2 = 50 volts. This applies whenever you know how much energy is associated with a known quantity of charge, for example in battery discharge calculations, particle physics experiments, or electric field problems.

Capacitor mode formula explained

A capacitor stores energy in its electric field according to E = (1/2) * C * V^2. Rearranging for voltage gives V = sqrt(2E / C). If a 10 mF (0.01 F) capacitor stores 100 J of energy, the voltage across it is sqrt(2 * 100 / 0.01) = sqrt(20000) which is approximately 141.4 V. This mode is useful in power electronics, energy storage systems, camera flash units, and any application where a capacitor bank stores and releases energy.

Reverse solve: finding energy from voltage

The reverse modes let you start with a known voltage and find the stored energy. For the charge reverse: E = V * Q. For the capacitor reverse: E = (1/2) * C * V^2. These are useful when you know the operating voltage of a system and need to work out the energy budget. For example, a 400 V electric vehicle battery pack with a 250 F equivalent capacitance stores 0.5 * 250 * 400^2 = 20,000,000 J = 20 MJ of energy.

Voltage classification by range

Voltage rangeClassificationTypical examplesHazard level
0-1 VMicro / signal voltageSensor outputs, logic signals Negligible
1-50 VLow voltage (safe touch)AA batteries (1.5 V), USB (5 V), car battery (12 V) Low
50-120 VIntermediate voltageUK/EU mains (230 V RMS), US mains (120 V RMS) Moderate
120-1000 VHigh voltageIndustrial motors, EV packs (400-800 V) High
> 1000 VExtra-high voltageTransmission lines, lightning (millions of V) Extreme

IEC and OSHA broadly classify voltages into these ranges for safety and equipment design purposes.

Frequently asked questions

Can I convert joules to volts without knowing the charge or capacitance?

No, it is not possible to convert joules to volts directly. Joules measure energy and volts measure electric potential; they are fundamentally different quantities. The link between them always requires a third quantity: either electric charge in coulombs (using V = E/Q) or capacitance in farads (using V = sqrt(2E/C)). If you know the charge or capacitance, this calculator handles the rest.

What is the formula for joules to volts?

There are two common formulas. In the charge-based formula, V = E / Q, where E is energy in joules and Q is charge in coulombs. In the capacitor formula, V = sqrt(2E / C), where C is capacitance in farads. The first follows from the SI definition of the volt (1 V = 1 J/C). The second comes from rearranging the capacitor energy equation E = (1/2) * C * V^2.

What voltage is considered safe to touch?

Most electrical safety standards, including IEC 60479, consider voltages below 50 V to be safe-touch in dry conditions. At 50 V and above, the risk of ventricular fibrillation increases, especially in wet or conductive environments. Household mains (120 V in North America, 230 V in Europe) are well above the safe-touch threshold and are hazardous.

How many joules does a 12 V car battery hold?

A typical 12 V car battery has a capacity of about 40-60 Ah (amp-hours). Converting 50 Ah to coulombs: 50 * 3600 = 180,000 C. Using E = V * Q = 12 * 180,000 = 2,160,000 J, or about 2.16 MJ. That is the total chemical energy; what is delivered as electrical energy depends on discharge efficiency.

What is the difference between a joule and a watt-hour?

A watt-hour (Wh) is the energy delivered by one watt for one hour. Since power in watts equals energy in joules per second, one watt-hour equals 3600 joules. Battery capacities are often rated in watt-hours: a 10 Wh phone battery holds 36,000 J of energy.

How do I convert millifarads or microfarads to farads for the capacitor mode?

Divide by the appropriate power of 1000. 1 millifarad (mF) = 0.001 F. 1 microfarad (uF) = 0.000001 F. 1 nanofarad (nF) = 0.000000001 F. Most electrolytic capacitors used in power supplies range from 100 uF to 10,000 uF (0.0001 F to 0.01 F), while supercapacitors used in energy storage can reach 1 to 3000 F.

Sources

Written by Grace Mbeki, MSc Data Scientist & Educator · Nairobi, Kenya

Turning everyday numbers into clear, actionable answers for the decisions that matter most.

Search 3,500+ calculators